A method for determining the concentration of hemoglobin in arterial blood, non invasively, is explored in this paper. A permanent magnet is placed just above the radial artery of a person whose hemoglobin concentration is to be ascertained. The flux produced by the permanent magnet (that links with the blood flow in the radial artery) is sensed to obtain a signal called magnetic plethysmogram (MPG). In this paper, an analytical model for a magnetic plethysmogram is derived. Using the proposed analytical model, a method of estimation of the concentration of hemoglobin in arterial blood is derived. The proposed method is then validated through a limited clinical study. The results of the clinical study establish the viability of measuring hemoglobin concentration, noninvasively, using magnetic plethysmogram.
机译:本文探讨了一种非侵入式测定动脉血中血红蛋白浓度的方法。永磁体正好放置在要确定其血红蛋白浓度的人的above动脉上方。感测由永磁体产生的通量(与the动脉中的血流相关联)以获得称为磁体积描记图(MPG)的信号。在本文中,得出了磁体积描记图的分析模型。使用所提出的分析模型,推导了估算动脉血中血红蛋白浓度的方法。然后通过有限的临床研究验证了所提出的方法。临床研究的结果证实了使用磁体积描记法无创地测量血红蛋白浓度的可行性。