首页> 外文会议>Conference on physics of medical imaging >QUANTITATIVE EVALUATION OF SUSCEPTIBILITY EFFECTS CAUSED BY DENTAL MATERIALS IN HEAD MAGNETIC RESONANCE IMAGING
【24h】

QUANTITATIVE EVALUATION OF SUSCEPTIBILITY EFFECTS CAUSED BY DENTAL MATERIALS IN HEAD MAGNETIC RESONANCE IMAGING

机译:牙科磁共振成像中牙科材料引起的敏感性影响的定量评估

获取原文

摘要

This work quantitatively evaluates the effects induced by susceptibility characteristics of materials commonly used in dental practice on the quality of head MR images in a clinical 1.5T device. The proposed evaluation procedure measures the image artifacts induced by susceptibility in MR images by providing an index consistent with the global degradation as perceived by the experts. Susceptibility artifacts were evaluated in a near-clinical setup, using a phantom with susceptibility and geometric characteristics similar to that of a human head. We tested different dentist materials, called PAL Keramit, Ti6Al4V-ELI, Keramit NP, ILOR F, Zirconia and used different clinical MR acquisition sequences, such as "classical" SE and fast, gradient, and diffusion sequences. The evaluation is designed as a matching process between reference and artifacts affected images recording the same scene. The extent of the degradation induced by susceptibility is then measured in terms of similarity with the corresponding reference image. The matching process involves a multimodal registration task and the use an adequate similarity index psychophysically validated, based on correlation coefficient. The proposed analyses are integrated within a computer-supported procedure that interactively guides the users in the different phases of the evaluation method. 2-Dimensional and 3-dimensional indexes are used for each material and each acquisition sequence. From these, we drew a ranking of the materials, averaging the results obtained. Zirconia and ILOR F appear to be the best choice from the susceptibility artefacts point of view, followed, in order, by PAL Keramit, Ti6Al4V-ELI and Keramit NP.
机译:这项工作定量评估了牙科实践中常用的材料的磁化率特性对临床1.5T设备中头部MR图像质量的影响。所提出的评估程序通过提供与专家认为的整体退化一致的指标来测量由MR图像中的磁化率引起的图像伪影。使用具有人体敏感性和几何特征与人体头部相似的体模,在近乎临床的设置中评估了敏感性伪像。我们测试了不同的牙医材料,分别称为PAL Keramit,Ti6Al4V-ELI,Keramit NP,ILOR F,氧化锆,并使用了不同的临床MR采集序列,例如“经典” SE和快速,梯度和扩散序列。评估被设计为参考和伪影受影响的记录同一场景的图像之间的匹配过程。然后根据与相应参考图像的相似性来测量由磁化率引起的退化程度。匹配过程涉及多模式注册任务,并使用基于相关系数在心理上经过验证的足够的相似性指标。所提出的分析被集成在计算机支持的过程中,该过程以交互方式指导用户使用评估方法的不同阶段。每种材料和每种采集顺序均使用二维和三维索引。从中,我们对材料进行了排名,对获得的结果进行平均。从敏感性制品的角度来看,氧化锆和ILOR F似乎是最佳选择,其次是PAL Keramit,Ti6Al4V-ELI和Keramit NP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号