A laboratory method has been developed to evaluate the thermal barrier performance of protective fabrics with a carbon dioxide (CO_2) laser. This experiment can apply high-intensity heat flux (up to 50 cal/cm~2s) to a fabric test specimen for a short duration (on the order of 100 ms) over a surface area of approximately 6 cm2. With these intensity and duration levels, results from the CO_2 laser test can be compared to those from ASTM F1959, which evaluates and rates the thermal protection performance of fabrics exposed to the controlled discharge of an electric arc. The CO_2 laser test uses the same analysis technique as that of ASTM F1959 to rate materials for thermal barrier performance. Data from both test methods are presented for several flame-resistant and protective fabrics. An advantage of the CO_2 laser test is the precision of thermal input to the test specimen. Differences in the contact between the test specimen and the calorimeter surface greatly affect the results of the CO_2 laser test. Developing a simple and repeatable technique to control this contact was achieved with two different configurations. Certain fabrics tended to deform when heated, which changed this contact and affected the test results. The closest correlation between the CO_2 laser test and arc rating test was achieved with an air gap spacer between the test specimen and calorimeter.
机译:已经开发了一种实验室方法来评估二氧化碳(CO_2)激光对防护织物的隔热性能。该实验可以在大约6 cm2的表面积上短时间(约100 ms)对织物试样施加高强度的热通量(高达50 cal / cm〜2s)。通过这些强度和持续时间水平,可以将CO_2激光测试的结果与ASTM F1959的结果进行比较,ASTM F1959可以评估和评估暴露于受控电弧放电下的织物的热防护性能。 CO_2激光测试使用与ASTM F1959相同的分析技术来评估材料的热障性能。两种测试方法的数据均针对几种阻燃和防护织物给出。 CO_2激光测试的一个优点是可以精确地输入到试样中。试样和量热仪表面之间的接触差异极大地影响了CO_2激光测试的结果。开发一种简单且可重复的技术来控制这种接触是通过两种不同的配置实现的。某些织物在加热时易于变形,从而改变了这种接触并影响了测试结果。使用试样和量热仪之间的气隙垫片,可以实现CO_2激光测试和电弧额定值测试之间的最密切相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号