首页> 外文会议>ASME turbo expo: turbine technical conference and exposition >A DETAILED UNCERTAINTY ANALYSIS OF ADIABATIC FILM COOLING EFFECTIVENESS MEASUREMENTS USING PRESSURE SENSITIVE PAINT
【24h】

A DETAILED UNCERTAINTY ANALYSIS OF ADIABATIC FILM COOLING EFFECTIVENESS MEASUREMENTS USING PRESSURE SENSITIVE PAINT

机译:压敏涂料对绝热膜冷却效率测量的不确定度分析

获取原文

摘要

Pressure sensitive paint (PSP) can be a powerful tool in measuring the adiabatic film cooling effectiveness. There are two distinct sources of error for this measurement technique; the ability to experimentally obtain the data and the validity of the heat and mass transfer analogy for the problem being studied. This paper will assess the experimental aspect of this PSP measurement specifically for film cooling applications. Experiments are conducted in an effort to quantifiably bound expected errors associated with temperature non-uniformities in testing and photo-degradation effects. Results show that if careful experimental procedures are put in place, both of these effects can be maintained to have less than 0.022 impact on effectiveness. Through accurate semi-in-situ calibration down to 4% atmospheric pressure, the near-hole distribution of effectiveness is measured with high accuracy. PSP calibrations are performed for multiple coupons, overmultiple days. In addition, to reach a partial pressure of 0 the calibration vessel was purged of all air by flowing CO_2. The primary contribution of this paper lies in the uncertainty analysis performed on the PSP measurement technique. A thorough uncertainty analysis is conducted and described, in order to completely understand the presented measurements and any shortcomings of the PSP technique. This quantification results in larger, albeit more realistic, values of uncertainty, and helps provide a better understanding of film cooling effectiveness measurements taken using the PSP technique. The presented uncertainty analysis takes into account all random error sources associated with sampling and calibration, from intensities to effectiveness. Adiabatic film cooling effectiveness measurements are obtained for a single row of film cooling holes inclined at 20 degrees, with CO_2 used as coolant. Data is obtained for six blowing ratios. Maps of uncertainty corresponding to each effectiveness profile are available for each test case. These maps show that the uncertainty varies spatially over the test surface, high effectiveness corresponds to low uncertainty. The noise floors can be as high as 0.04 at effectiveness levels of 0. Day-to-day repeatability is presented for each blowing ratio and shows that laterally averaged effectiveness data is repeatable within 0.02 effectiveness.
机译:压敏涂料(PSP)是测量绝热膜冷却效果的有力工具。此测量技术有两个不同的误差源;通过实验获得数据的能力以及对所研究问题进行传热和传质类比的有效性。本文将评估该PSP测量的实验方面,专门针对薄膜冷却应用。进行实验是为了量化与测试和光降解效应中温度不均匀性相关的预期误差。结果表明,如果采取了周密的实验程序,则可以保持这两种效果对有效性的影响小于0.022。通过低至4%大气压的精确半原位校准,可以高精度测量近孔有效性分布。对多张优惠券进行PSP校准,需要连续数天。另外,为了达到分压0,通过流动CO_2清除校准容器中的所有空气。本文的主要贡献在于对PSP测量技术进行的不确定性分析。进行并进行了彻底的不确定性分析,以完全理解所提出的测量结果和PSP技术的任何缺点。这种量化可以带来更大,更现实的不确定性值,并有助于更好地理解使用PSP技术进行的薄膜冷却效果测量。提出的不确定性分析考虑了与采样和校准相关的所有随机误差源,从强度到有效性。对于倾斜20度的单排薄膜冷却孔,使用CO_2作为冷却剂,获得了绝热薄膜冷却效果的测量值。获得了六个吹风比的数据。每个测试用例都可以找到与每个有效性概况相对应的不确定性图。这些图表明,不确定性在测试表面上在空间上有所变化,高有效性对应于低不确定性。在0的有效水平下,本底噪声可以高达0.04。每个吹风比的日常重复性均得到显示,并显示横向平均有效性数据在0.02的有效性内是可重复的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号