首页> 外文会议>IEEE Nuclear Science Symposium and Medical Imaging Conference >Mechanically stable metal layers for ohmic and blocking contacts on CdZnTe detectors by electroless deposition
【24h】

Mechanically stable metal layers for ohmic and blocking contacts on CdZnTe detectors by electroless deposition

机译:通过化学沉积在CdZnTe检测器上用于欧姆接触和阻挡接触的机械稳定金属层

获取原文

摘要

CdZnTe detectors are commonly exploited for the detection of gamma rays. However, obtaining mechanical stable, low noise contacts on CdZnTe is still an issue. In particular, ohmic contacts would be preferable for high flux applications. In this work, we show that it is possible to obtain mechanical stable gold contacts by electroless deposition in methanol solution. Moreover, we show that electroless deposited nickel contacts are also mechanical stable and are good candidates for the realization of ohmic contacts on high resistivity CdZnTe crystals.
机译:CdZnTe检测器通常用于检测伽玛射线。但是,在CdZnTe上获得机械稳定,低噪声的接触仍然是一个问题。特别地,对于高通量应用,欧姆接触将是优选的。在这项工作中,我们表明可以通过在甲醇溶液中化学沉积获得机械稳定的金触点。此外,我们表明,化学沉积的镍触点也具有机械稳定性,并且是在高电阻率CdZnTe晶体上实现欧姆触点的良好候选者。