首页> 外文会议>IEEE International Ultrasonics Symposium >A PMN-PT micromachined 1–3 composite circular array for IVUS
【24h】

A PMN-PT micromachined 1–3 composite circular array for IVUS

机译:用于IVUS的PMN-PT微加工的1-3复合圆阵列

获取原文

摘要

In this paper, a single crystal PMN-PT micromachined 1-3 composite circular array (50 element, ~2.2 mm in diameter) was developed for intravascular ultrasound (IVUS) imaging. Micromachined 1-3 composites with frequency of XX MHz were first fabricated and tested. Array elements with a pitch of 140-micron were interconnected via a customized flexible circuit. Pulse-echo tests showed the average center frequency of 40 MHz and the -6 dB fractional bandwidth of 62% for array elements. The -20 dB pulse length was evaluated as 118 ns. The measured crosstalk is less than - 24 dB between adjacent elements. An image of 50 μm steel wire targets was acquired by stacking multiple A-lines. The results demonstrated beam widths exceeding 70 μm axially. Those results imply the great potential of the developed array transducer for the high frequency medical imaging.
机译:在本文中,开发了单晶PMN-PT微机械加工的1-3复合圆形阵列(50个元素,直径约为2.2毫米),用于血管内超声(IVUS)成像。首先制造并测试了频率为XX MHz的微机械1-3复合材料。间距为140微米的阵列元件通过定制的柔性电路互连。脉冲回波测试显示,阵列元件的平均中心频率为40 MHz,-6 dB的分数带宽为62%。 -20 dB脉冲长度评估为118 ns。相邻元件之间测得的串扰小于-24 dB。通过堆叠多条A线获得50μm钢丝靶材的图像。结果表明,轴向光束宽度超过70μm。这些结果暗示了开发的阵列换能器在高频医学成像中的巨大潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号