首页> 外文会议>Power plant pollutant control "MEGA" symposium >Overview of HCl Monitoring Technologies
【24h】

Overview of HCl Monitoring Technologies

机译:HCl监测技术概述

获取原文

摘要

1. Overall the HCICEMS performed very well(considering limited operating experience on coal-fired plants) 2. The HCl response from the FTIR and CRDS systems from October 2013 - January 2014 consistently followed the same trend 3. The absolute avg. difference between the Thermo FTIR and Spectrum-Tiger Optics CRDS (@1,769 hours) was ~0.1 ppmw 4. Average absolute difference between two TDL-based instruments during the same time period was ~0.4 ppmw 4.1 However, the difference between the two TDL-based instruments did drop to ~0.2 ppmw after Cemtek-Unisearch implemented their moisture correction routine in early December 2013.
机译:1.总体而言,HCICEMS表现良好(考虑到燃煤电厂的有限运行经验)2. 2013年10月至2014年1月,FTIR和CRDS系统对HCl的反应始终遵循相同的趋势3.绝对平均值。 Thermo FTIR和Spectrum-Tiger Optics CRDS(@ 1,769小时)之间的差异为〜0.1 ppmw。4.同一时期内两种基于TDL的仪器之间的平均绝对差值为〜0.4 ppmw 4.1。在Cemtek-Unisearch于2013年12月上旬实施其湿度校正程序后,基于这种仪器的仪器的确下降到了约0.2 ppmw。