首页> 外文会议>ASME Pressure Vessels and Piping conference >FREQUENTLY OVERLOOKED HEAT EXCHANGER DESIGN CONDITIONS
【24h】

FREQUENTLY OVERLOOKED HEAT EXCHANGER DESIGN CONDITIONS

机译:频繁超载的换热器设计条件

获取原文

摘要

This paper explores the current design methodology for heat exchanger channel pass partition plates using ASME and TEMA design rules. Unanticipated elevated stress levels above allowable stress may exist at the channel pressure boundary due to differential pressure. In performing finite element analysis on two-pass heat exchanger channel geometry, elevated bending stress magnitudes were identified on the channel pressure boundary in the vicinity of the pass partition plate. These elevated stresses are induced by the pressure drop across channel passes, which load the pass partition plate and subject the channel pressure boundary to a bending stress which is frequently not evaluated. The combined membrane and bending stress may exceed allowable limits. This paper is intended to highlight this potentially overlooked loading condition in the design of heat exchanger channels.
机译:本文探讨了使用ASME和TEMA设计规则的热交换器通道通道隔板的当前设计方法。由于压差,在通道压力边界可能会出现超出允许应力的意外升高应力水平。在对两通道换热器通道几何形状进行有限元分析时,在通道隔板附近的通道压力边界上发现了较高的弯曲应力大小。这些升高的应力是由通道通道上的压降引起的,通道通道上的压降会给通道分隔板加载,并使通道压力边界经受弯曲应力,而弯曲应力通常无法评估。膜和弯曲应力的总和可能超过允许的极限。本文旨在强调在热交换器通道设计中这种可能被忽略的负载情况。