首页> 外文会议>IEEE Nuclear Science Symposium and Medical Imaging Conference >Image recovery in PET scanners with partial detector rings using compressive sensing
【24h】

Image recovery in PET scanners with partial detector rings using compressive sensing

机译:使用压缩感测的PET扫描仪在PET扫描仪中恢复

获取原文

摘要

Most PET scanners consist of tightly packed discrete detector rings to improve scanner efficiency. Our aim in this paper was to investigate the possibility of reducing the number of detector elements per ring (introduce gaps) while maintaining image quality by employing compressed sensing (CS) techniques. A uniform Ge-68 phantom (20 cm diameter and length) was imaged on a D-RX PET/CT scanner twice; once with all detectors operational (gold standard) and once with 4 detector blocks at each of 0, 90, 180 and 270 degrees turned off (partially sampled, 11 % off). Image recovery of the partially observed data was performed by minimizing the Total Variation (TV) of the derivatives of adjacent pixels in the image domain, while imposing a linear constraint of equity the product of system matrix and recovered image to the partially observed data. This minimization was repeated iteratively for a total of 100 iterations. The resultant corrected Image was then multiplied by the system matrix and the resultant sinogram was compared to the measured sinogram. In addition, the mean and maximum activity concentration in a ROI placed centrally over the phantom was computed between the resultant CS image, fully observed image (no gap- gold standard), and the partially sampled (with detector gap) image. The results of the CS recovery showed that the mean and maximum activity concentration difference in the recovered image was -0.74% and 2.27% respectively when compared to the gold standard while those for the partially observed images were 4.25% and 20%. Compressed sensing using TV approaches seems to be capable of generating accurate quantification of activity concentration from a partially sampled data set.
机译:大多数PET扫描仪由紧密包装的离散探测器环组成,以提高扫描仪效率。我们本文的宗旨是探讨通过采用压缩感测(CS)技术来减少每环(引入间隙)的检测器元素数量的可能性。在D-RX PET / CT扫描仪上成像均匀的GE-68幻影(直径20厘米和长度);一旦使用所有探测器运行(金标准),并且在0,90,180和270度中的每一个中的4个检测器块一次关闭(部分采样,11%)。通过最小化图像域中的相邻像素的衍生物的总变化(TV)来执行部分观察到的图像的图像恢复,同时将系统矩阵的乘积和恢复图像施加到部分观察到的数据。迭代地重复这种最小化,总共100次迭代。然后将所得校正的图像乘以系统矩阵,并将所得的Sinogram与测量的铭文进行比较。另外,在所得CS图像,完全观察的图像(无间隙 - 金标准)和部分采样(用探测器间隙)图像之间计算集中放置在幽灵上的ROI中的平均值和最大活度浓度。 CS回收结果表明,与金标准相比,回收图像中的平均值和最大活性浓度差异分别为-0.74%和2.27%,而部分观察到的图像的图像分别为4.25%和20%。使用电视方法的压缩感测似乎能够从部分采样的数据集产生精确定量的活动浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号