This work provides a critical analysis of the point source methodology applied in nuclear medicine radioactivity waste management routine. To evaluate the point source approximation used in the practice to determine the activity and its effect on activity and storage time was used deterministic and Monte Carlo calculations. The first step of this work was to validate the Monte Carlo Geant4 toolkit using measurements with standard calibration sources. After that the deterministic and Monte Carlo calculation was performed. In a realistic geometry the waste is not a point source but a box of dimensions (30.5 x 31.5 x 25.0) cm~3. The impact on activity estimation comparing the real source point to the box geometry was observed from 20% up to 800% depending on the distance between the source and the detector and the selected radionuclide. The simple case evaluated in this work considering different radioisotopes proves that uses the point source approximation cause significant influence on the activity estimation. However it does not have significant impact in the storage time. The non significant influence in time storage can be explained by the activity limits recommend to release the radioactive waste that is significant smaller than the initial activity and the exponential behavior of the radioactive decay associated to value of the physical disintegration constant for the radionuclide commonly used on nuclear medicine applications.
机译:这项工作提供了对核医学放射性废物管理常规应用点源方法的关键分析。为了评估在实践中使用的点源近似,以确定活动及其对活动和储存时间的影响,确定性和蒙特卡罗计算。这项工作的第一步是使用标准校准源的测量来验证Monte Carlo Geant4 Toolkit。之后,进行确定性和蒙特卡罗计算。在一个现实的几何形状中,废物不是点源,而是一盒尺寸(30.5 x 31.5 x 25.0)cm〜3。根据源和检测器之间的距离和所选放射性核素之间的距离,从20%高达800%观察到对箱几何的对框几何进行比较的影响。考虑到不同放射性同位素的这种工作中评估的简单案例证明了使用点源近似对活动估计产生重大影响。但它在储存时间没有显着影响。可以通过活动限制来解释在时间储存中的非显着影响力建议释放小于初始活动的放射性废物,以及与常用的放射核素的物理崩解常数的物理崩解常数相关的放射性衰减的指数行为核医学应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号