The performance of a group of 16 American (US) breast screening radiologists in interpreting a number of cases from a recent PERFORMS self-assessment case set which had been carefully selected to exclude small calcifications, using sub-mammographic resolution displays, as compared to a British (UK) group of radiologists using mammographic displays has previously been reported. It was found that the UK group performed better, detecting more cancers with the US participants correctly recalling less. These results were interpreted as due to differences in the displays employed by each group as well as to routine screening differences between the two countries. This current study extended that work with 11 of these experienced US breast screening radiologists further interpreting 20 new PERFORMS mammographic cases using a suitable mammographic clinical workstation. The PERFORMS cases were selected so as to show a range of normal, benign and abnormal appearances. Data from these radiologists were compared to their earlier performance on different PERFORMS cases and sub-clinical displays. Their data were also compared to recent data of 11 UK radiologists reading the same cases, again on clinical workstations as well as to all UK screeners. Despite using equivalent clinical monitors, data indicate differences between the UK and US groups in recall decisions which is not just a function of the countries' screening approaches. Lower detection of abnormal cases by the US group was found here and reasons for this are explored.
机译:一组16位美国(美国)乳房筛查放射科医生在解释最近的PERFORMS自我评估案例集中的许多案例方面的表现,这些案例是经过精心选择以排除小钙化的结果,使用了X线乳房X线照片分辨率显示,相比之下,以前有英国(UK)的放射线专家使用乳腺X线照片显示的报道。结果发现,英国小组的表现更好,在美国参与者正确召回的情况下,发现了更多的癌症。这些结果被解释为是由于每个小组采用的显示方式不同以及两国之间的常规筛查差异所致。这项当前的研究扩展了与这些经验丰富的美国乳腺癌筛查放射科医生中的11名的合作关系,并使用合适的乳腺X射线摄影临床工作站进一步解释了20例新的PERFORMS乳腺X射线摄影病例。选择PERFORMS案例以显示一系列正常,良性和异常的外观。将这些放射科医生的数据与他们在不同的PERFORMS病例和亚临床显示器上的早期表现进行了比较。他们的数据也与11名英国放射科医生最近的数据进行了比较,他们再次在临床工作站上以及所有英国筛查人员中读取了相同的病例。尽管使用了等效的临床监测器,但数据表明,在召回决定中,英美两国之间存在差异,这不仅是各国筛查方法的作用。美国小组发现的异常病例的检出率较低,并探讨了造成这种情况的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号