首页> 外文会议>Corrosion conference and expo >MIC in a CO_2 Gathering line? A Field Case Study of Microbiologically Influenced Corrosion
【24h】

MIC in a CO_2 Gathering line? A Field Case Study of Microbiologically Influenced Corrosion

机译:MIC在CO_2集线中?微生物腐蚀的现场案例研究

获取原文

摘要

It is often said that it is difficult to prove directly that microbiologically influenced corrosion (MIC) is the cause of failure. Rather, it is through the process of eliminating other corrosion mechanisms that MIC can be identified. This paper presents the failure analysis of leaks on a CO_2 gathering pipeline that concluded that microbiologically influenced corrosion was the primary failure mechanism. The challenges of MIC control and lessons learned are presented.
机译:经常有人说,很难直接证明微生物影响的腐蚀(MIC)是失败的原因。而是,通过消除其他腐蚀机制的过程可以确定MIC。本文介绍了CO_2收集管道泄漏的失效分析,得出的结论是微生物影响的腐蚀是主要的失效机理。介绍了MIC控制的挑战和经验教训。