The work described in this paper reports on the additional research and development conducted in support of the Risk-informed Over Deterministic (RoverD) approach to address the concerns raised in Generic Safety Issue 191 (GSI-191). In this work, a method is developed using a RELAP5-3D PWR model coupled with a MELCOR large, dry containment model to obtain conservative containment pressure estimates used together with conservative sump pool temperature estimates in order to comply with the regulatory guidance. The current regulatory guidance on Emergency Core Cooling System (ECCS) performance, "Revised Content Guide for Generic Letter 2004 02 Supplemental Responses, November 2007" (ADAMS Accession No. ML073110278), and Regulatory Guide 1.82, "Water Sources for Long Term Recirculation Cooling Following a Loss of Coolant Accident, " is briefly reviewed as it applies to flashing in the ECCS pumping system. Because the guidance does not specify the method that should be used to comply with the conservative assumptions, an acceptable approach must be developed by the utility engineer.
机译:本文中描述的工作报告了支持额外的研发,以支持风险知识的确定性(Roverd)方法,以解决通用安全问题191(GSI-191)中提出的担忧。在这项工作中,使用Relap5-3D PWR模型开发了一种方法,该方法与熔体大,干燥容纳模型相结合,以获得与保守的漏气池温度估计一起使用的保守遏制压力估计,以符合监管指导。紧急核心冷却系统(ECCS)性能的当前监管指导,“通用信件内容指南2004年02份补充响应”(ADAMS登录号ML073110278)和监管指南1.82,“长期再循环冷却的水源”在丧失冷却液事故之后,“简要审查,因为它适用于ECCS泵送系统的闪烁。由于指导不指定应使用的方法来符合保守假设,因此必须由公用事业工程师开发可接受的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号