首页> 外文会议>Asia-Pacific Microwave Conference >Measurement of Transmission Line Characteristics Using Linear Resonator Technique in Millimeter-wave/Terahertz-wave regions
【24h】

Measurement of Transmission Line Characteristics Using Linear Resonator Technique in Millimeter-wave/Terahertz-wave regions

机译:毫米波/太赫兹波区中线性谐振器技术测量传输线特性

获取原文

摘要

This paper presents a measurement technique and measured results of transmission line characteristics in millimeter-wave and Terahertz frequency regions. Linear resonator technique was employed in the measurement. Formulas for transmission performance of the resonator with gaps coupling to the measurement system, and a simple formula for compensation of the resonant frequency shift from the true resonance due to the coupling have been presented. Microstrip lines fabricated on a 50μm-thick liquid crystal polymer (LCP) substrate were used in our experiment. Measured results of transmission line characteristics such as effective dielectric constant, attenuation constant and Q-factor from 220 GHz to 330 GHz, have been provided.
机译:本文介绍了毫米波和太赫兹频率区中传输线特性的测量技术和测量结果。测量中采用线性谐振器技术。具有间隙耦合到测量系统的谐振器的传输性能的公式,并且已经介绍了从耦合引起的真正共振补偿的简单公式。在我们的实验中使用了在50μm厚的液晶聚合物(LCP)底物上制造的微带线。已经提供了传输线特性的测量结果,例如有效介电常数,衰减常数和来自220GHz至330 GHz的Q系数。