The City of Winnipeg Water and Waste Department initiated a Combined SewerOverflow (CSO) Outfall Monitoring Program with the installation of fifteen full scale pilotmonitoring sites between June 2009 and April 2010. The overall goal of the CSO MonitoringProgram is to develop a permanent monitoring system to accurately detect and quantify CSOevents. The system is also being provisioned to enable future real-time reporting of overflowevents.During the project’s two pilot phases, monitoring sites were instrumented with a combination offlowmeters, level meters, and inclinometers. Data analysis from these first installationsdetermined the most efficient ways to monitor CSOs. Different monitoring strategies weredeveloped and evaluated as part of a cost-benefit analysis for future site instrumentation. Basedon this analysis, the recommendation for the ongoing monitoring program was to primarily relyon a combination of level meters and inclinometers. These have proven to be reliable instrumentsand will provide redundancy in detecting overflows. It was also recommended to use a calibratedhydraulic model to estimate overflow volume. A model can provide sufficient accuracy forreporting purposes and is an interesting and cost-effective alternative when compared to the useof flowmeters. Further, experience gained from the pilot phases has shown that hydraulicconditions were not, for the most part, conducive to accurate and reliable flow gauging. Using areal-time model application can be a reliable tool and has the added advantage of offering manyother benefits to the City’s operation and planning functions.Status of Completion: Phases 1 and 2 of the project are complete with 15 sites instrumented andoperational. Design for the installation of ten additional sites (Phase 3) is currently underway.Commissioning of these sites and the development of an online data management, real timemodel, and reporting application is due at the end of 2012.
机译:温尼伯市水和废物部门启动了联合下水道 安装了十五个全尺寸试点的溢流(CSO)排污监控程序 在2009年6月至2010年4月期间进行监控。CSO监控的总体目标 计划是开发一个永久性的监控系统,以准确地检测和量化CSO 事件。还提供了该系统以实现将来的溢出实时报告 事件。 在该项目的两个试点阶段中,对监测站点进行了综合检测, 流量计,液位计和倾角仪。这些首次安装的数据分析 确定了监视公民社会组织的最有效方法。不同的监测策略是 作为成本效益分析的一部分进行开发和评估,以用于将来的现场仪表。基于 根据此分析,对正在进行的监视程序的建议主要是 在液位计和测斜仪的组合上。这些已被证明是可靠的工具 并将在检测溢出方面提供冗余。还建议使用经过校准的 水力模型来估计溢流量。一个模型可以为 报告的目的,与使用相比是一种有趣且具有成本效益的选择 流量计。此外,从试点阶段获得的经验表明,液压 在大多数情况下,这些条件不利于进行精确可靠的流量测量。用一个 实时模型应用程序可以是可靠的工具,并具有提供许多其他功能的附加优势。 纽约市的运营和计划功能的其他好处。 完工状况:该项目的第1和第2阶段已经完成,有15个站点进行了检测, 操作。目前正在设计另外十个站点的安装(第3阶段)。 这些站点的调试和在线数据管理的实时开发 模型,并且报告申请将于2012年底提交。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号