首页> 外文会议>IEEE International Symposium on Circuits and Systems >A Preamplifier for the Front-End Readout System of Particles Tracking in Secondary Electron Detectors
【24h】

A Preamplifier for the Front-End Readout System of Particles Tracking in Secondary Electron Detectors

机译:二次电子检测器中粒子前端读出系统的前端放大器

获取原文

摘要

This paper presents the design and characterization of a preamplifier used in the electronic front-end of low-pressure gaseous secondary electron detectors. The circuit - implemented in a printed circuit board as a proof of concept - has been designed to cope with the specifications of the readout electronics used in spatial resolution measurements. Experimental results show a transimpedance gain of 80dB, an overall voltage gain of 18 dB, a peak signal-to-noise ratio of 36.5 dB and a shaping time frame of 140-170ns. These features improve the performance of previous reported approaches to the problem, and allow us to minimize the overlapping probability in secondary electron detections for radioactive ion beams tracking, achieving a counting rate higher than 10~6 particles per second.
机译:本文介绍了低压气体二次电子检测器的电子前端中使用的前置放大器的设计和表征。电路 - 在印刷电路板中实现作为概念的证据 - 已经设计用于应对空间分辨率测量中使用的读出电子器件的规格。实验结果显示了80dB的横阻增益,总电压增益为18dB,峰值信噪比为36.5dB,成形时间帧为140-170ns。这些特征提高了先前报告的问题方法的性能,并允许我们最小化放射性离子束跟踪的二次电子检测中的重叠概率,从而实现每秒高于10〜6颗粒的计数率。