首页> 外文会议>International conference on Frontiers of advanced materials and engineering technology >Effect of Cold Energy Storage of single-well Aquifer Thermal Energy Storage in Sanhejian Coal Mine
【24h】

Effect of Cold Energy Storage of single-well Aquifer Thermal Energy Storage in Sanhejian Coal Mine

机译:三河煤矿单井含水液热能储存冷储能的影响

获取原文

摘要

Effective implementation of technology of aquifer thermal energy storage(ATES) must form a "ground cold water reservoir" or "ground warm reservoir".In this paper,taking Sanhejian Coal Mine as an example,we analyze the effect of cold energy storage in single-well by analyzing the volume change of cold water body within different temperature ranges.Through the analysis of volume change of cold water body,it can prove that with the same irrigation temperature,the increase of irrigation flow makes the volume and percentage of cold water body in aquifer within different temperature ranges.And the impact on the cold water of 2-5°C is more obvious.With the same irrigation flow,both the cold water body and its percentage of 2-10°C in the condition of 2°C irrigation temperature are more than those in the condition of 5°C.The increase of irrigation flow and the decrease of irrigation temperature are beneficial to cold energy storage,and the effect of cold energy storage of the condition 3 (100m3/h irrigation flow and 2°C irrigation temperature) is the best in these four conditions.
机译:有效实施含水层热能储存(ATES)的技术必须形成“地面冷水储层”或“地面温水库”。本文以三河江煤矿为例,我们分析了单身冷能量储存的影响 - 通过分析不同温度范围内的冷水体的体积变化。用冷水体积变化分析,可以证明具有相同的灌溉温度,灌溉流量的增加使得冷水的体积和百分比在不同温度范围内的含水层的身体。在2-5°C的冷水上的影响更为明显。与相同的灌溉流动,冷水机身和2-10°C的百分比为2 °C灌溉温度大于5°C条件的温度。灌溉流量的增加和灌溉温度降低有利于冷能量储存,以及条件3的冷能量储存的影响(100m3 / h灌溉流量和2°C灌溉温度)是这四种条件中最好的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号