首页> 外文会议>ISES-Europe solar conference >Thermal performance of marketed SDHW systems under laboratory conditions
【24h】

Thermal performance of marketed SDHW systems under laboratory conditions

机译:市售SDHW系统在实验室条件下的热性能

获取原文

摘要

A test facility for solar domestic hot water systems, SDHW systems was established at the Technical University of Denmark in 1992. During the period 1992-2012 21 marketed SDHW systems, 16 systems from Danish manufacturers and 5 systems from manufacturers from abroad, have been tested in the test facility under the same realistic test conditions. The systems had different designs and sizes. Each system was tested during a long test period consisting of both a summer and winter period. Detailed simulation models for each system were developed. The simulation models were modified and the input to the models were fitted in such a way, that the calculated thermal performance is in good agreement with the measured thermal performance, both for a typical winter period and for a typical summer period. In this way it is possible to use the simulation models to calculate the yearly thermal performance of the tested systems with weather data from the Danish Test Reference Year and with the same hot water consumption. The tests showed that the designs of the heat storage and that the system concepts are of vital importance for the thermal performances of the systems and that neither the solar collector efficiency nor the solar collector area is influencing the thermal performance as much as the heat storage design and the system concept. The tests also showed that all the tested systems can be improved with relative simple design changes. Based on the tests it is concluded that high thermal performances of SDHW systems are achieved by reducing the heat loss from the upper part of the heat stores to a minimum by having no pipes connected to the upper part of the tank, reducing the auxiliary volume at the top of the heat stores as much as possible, of course with consideration of the required hot water comfort, avoiding simple errors, using the low flow principle and heat stores with a high degree of thermal stratification and by using components with good thermal characteristics.
机译:SDHW系统是太阳能家用热水系统的测试设施,于1992年在丹麦技术大学成立。在1992年至2012年期间,已经测试了21种市售的SDHW系统,丹麦制造商的16个系统和国外制造商的5个系统。在相同现实测试条件下的测试设备中。该系统具有不同的设计和尺寸。每个系统都在包括夏季和冬季在内的较长测试期间内进行了测试。为每个系统开发了详细的仿真模型。修改了仿真模型,并以这种方式拟合了模型的输入,以使得在典型的冬季和典型的夏季,所计算的热性能与测得的热性能非常吻合。这样,可以使用仿真模型通过丹麦测试参考年的天气数据和相同的热水消耗量来计算被测系统的年度热性能。测试表明,蓄热器的设计和系统概念对于系统的热性能至关重要,并且太阳能集热器效率和太阳能集热器面积对热量性能的影响都不会像蓄热器设计那样重要。和系统概念。测试还表明,可以通过相对简单的设计更改来改进所有测试的系统。根据测试得出的结论是,通过不将任何管道连接到储罐的上部,将储热罐上部的热损失降至最低,从而实现SDHW系统的高热性能,从而减小了储罐上部的辅助容积。当然,考虑到所需的热水舒适性,避免简单的错误,使用低流量原理以及热分层程度高的储热器以及使用具有良好热特性的组件,应尽可能地提高储热器的顶部。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号