This paper discusses the improvements made to the multiple hearth incinerator (MHI) at theadvanced water reclamation facility (AWRF) located in Brockton, Massachusetts. The MHI isused for thermal reduction of the residual solids generated at the city’s AWRF. In the past, thecity had encountered operational challenges with the MHI, including high maintenance due toslag and clinker formation, incomplete burning of the solids due to balling of the solids feed, andlimited capacity. In addition, stringent U.S. Environmental Protection Agency (USEPA) sewagesludge incinerator (SSIs) regulations had been proposed that put continued use of the MHI injeopardy.In June 2009, the city authorized CDM Smith to perform a preliminary design and eventually afinal design of upgrades to the MHI. Upgrades to the MHI included installation of a flue gasrecirculation (FGR) system to improve emissions and to reduce slag and clinker formation,replacement of the existing wet scrubber with a multi-venturi scrubber, and significant otherimprovements and repairs to the incinerator. Construction was completed in fall 2010 andemissions compliance testing was conducted on January 21 and 22, 2011.This paper will also discuss the air permitting process with the Massachusetts Department ofEnvironmental Protection (MADEP). MADEP required that air dispersion modeling of theincinerator’s emission limits be conducted. The air modeling demonstrated that the incineratormeets the MADEP’s Allowable Ambient Limits (AALs) and Threshold Effect Exposure Limits(TELs), as well as the National Ambient Air Quality Standards (NAAQS). Final compliancetesting of the incinerator emissions demonstrated that the incinerator met the recently finalizedUSEPA sewage sludge incinerator regulations (40 CFR Part 60, Subpart MMMM).
机译:本文讨论了对多炉膛焚烧炉(MHI)的改进。 位于马萨诸塞州布罗克顿的高级水回收设施(AWRF)。三菱重工是 用于减少城市AWRF产生的残余固体的热量。过去, 该市在三菱重工(MHI)方面遇到了运营挑战,包括由于 炉渣和熟料的形成,由于固体进料形成的球状而导致的固体不完全燃烧以及 容量有限。此外,美国环境保护局(USEPA)的污水处理十分严格 提出了污泥焚烧炉(SSIs)法规,该法规将MHI继续用于 危险。 2009年6月,该市授权CDM Smith进行初步设计,并最终进行了设计。 MHI升级的最终设计。升级到三菱重工(MHI)包括安装烟气 再循环(FGR)系统,以改善排放并减少炉渣和熟料的形成, 用多文丘里洗涤器代替现有的湿式洗涤器,以及其他 焚化炉的改进和修理。工程于2010年秋季完工, 排放合规性测试于2011年1月21日至22日进行。 本文还将与马萨诸塞州部门讨论空气许可过程。 环境保护(MADEP)。 MADEP要求对空气扩散建模 进行焚化炉的排放限值。空气模型表明焚烧炉 符合MADEP的允许环境限值(AAL)和阈值影响暴露限值 (TELs)以及国家环境空气质量标准(NAAQS)。最终合规 对焚化炉排放物的测试表明,焚化炉符合最近确定的条件 USEPA污水污泥焚烧炉法规(40 CFR第60部分,MMMM子部分)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号