We have designed and fabricated a micro flow cytometer for application to bacteria detection. In this paper, we present a CAD study which has been done to obtain optimal working conditions of the device. In the simulation, we have investigated flow rate ratios of sample and sheath flow to confirm hydrodynamic focusing at a desired position and proper sample stream width at the detection position. As a result, we could obtain adequate flow rate ratios of sample and sheath flow, which is in the vicinity of 1:5 for our device. A bacteria enumeration experiment has also been carried out, based on the simulation results, and we have achieved hydrodynamic focusing at the expected position and proper sample flow rate.
机译:我们已经设计和制造了一种微流量富含细胞仪,以施用于细菌检测。在本文中,我们提出了一种已经完成的CAD研究,以获得设备的最佳工作条件。在模拟中,我们已经研究了样品和鞘流的流量比,以确认在检测位置处的所需位置和适当的样品流宽度的流体动力学聚焦。结果,我们可以获得样品和护套流量的足够的流量比,其在我们的装置附近为1:5。还基于模拟结果进行了细菌枚举实验,并且我们已经实现了在预期位置和适当的样品流速下的流体动力学聚焦。