DEVELOPMENT AND VALIDATION OF AN IN-VIVO FINITE ELEMENT PELVIS MODEL WITH CORTICAL THICKNESS MAPPED FROM A CADAVER

机译:从CADAVER绘制具有膜厚的体内有限元骨盆模型的开发和验证

获取原文

摘要

An in-vivo FE pelvis model of a 50th percentile male was developed and validated against experimental data. Inaccurate cortical thickness of the in-vivo pelvic bone was corrected by mapping the thickness from a cadaver study using the methods described. The results of quasi-static and dynamic impact simulation agreed well with experimental data. The cortical thickness mapping technique may be useful when developing other in-vivo FE bone models, where cadaver scan data are available.
机译:建立了第50个百分位男性的体内FE骨盆模型,并根据实验数据进行了验证。通过使用所述方法绘制尸体研究的厚度,可以校正体内骨盆骨的皮质厚度不正确。准静态和动态冲击仿真的结果与实验数据吻合良好。当开发其他尸体扫描数据可用的体内FE骨模型时,皮质厚度映射技术可能会很有用。