首页> 外文会议>European corrosion congress;EUROCORR 2011 >Corrosion behaviour of ZrN/Ti ceramic solid solution in fluids simulating biological inflammatory conditions
【24h】

Corrosion behaviour of ZrN/Ti ceramic solid solution in fluids simulating biological inflammatory conditions

机译:ZrN / Ti陶瓷固溶体在模拟生物炎症条件下的腐蚀行为

获取原文

摘要

When an implant is inserted into a living tissue, the response of the organism is always associated with an inflammatory process caused by the surgical intervention and/or the foreign materials. Therefore, for the evaluation of the biocompatibility, it is important to investigate the behaviour of materials under such conditions. In the current study the corrosion behaviour of a ZrN/Ti (ZNT) ceramic solid solution under inflammatory conditions was investigated and compared with CP Ti. The ZNT ceramic material was prepared by hot pressing and the presence of titanium in the solid solution showed some beneficial effect on sinterability and on mechanical properties, mainly hardness, if compared to monolithic ZrN. A phosphate buffer saline (PBS) solution (pH 7.4) and a PBS/0.1 M H_2O_2 (pH=4) solution were used to simulate the body fluids in the absence and in the presence of inflammatory conditions respectively. The corrosion behaviour of the materials was monitored by linear polarization resistance measurements and polarization curves for two weeks. After the first week the PBS/H2O2 solution was replaced by fresh PBS solution in order to simulate the normalization process after the acute inflammatory phase. The behaviour of the tested materials under inflammatory conditions was compared with that in the absence of an inflammatory process. For ZNT solid solution exposed to inflammatory conditions the results showed a better corrosion behaviour than that observed on CP Ti, as an effect of the formation of a more protective surface oxide layer. The electrochemical results and the mechanical properties of ZNT ceramic material suggest that it is a promising candidate for biomedical applications where high corrosion and wear resistance are required.
机译:当将植入物插入活组织中时,生物体的反应总是与外科手术和/或异物引起的炎症过程有关。因此,对于生物相容性的评价,重要的是研究在这种条件下材料的行为。在当前的研究中,研究了ZrN / Ti(ZNT)陶瓷固溶体在炎性条件下的腐蚀行为,并将其与CP Ti进行了比较。 ZNT陶瓷材料是通过热压制备的,与单块ZrN相比,固溶体中钛的存在对烧结性和机械性能(主要是硬度)有一些有益的影响。使用磷酸盐缓冲盐水(PBS)溶液(pH 7.4)和PBS / 0.1 M H_2O_2(pH = 4)溶液分别模拟在无炎症条件和有炎症条件下的体液。通过线性极化电阻测量和极化曲线监测材料的腐蚀行为两周。第一周后,用新鲜的PBS溶液代替PBS / H2O2溶液,以模拟急性炎症期后的正常化过程。将测试材料在炎性条件下的行为与不存在炎性过程的行为进行比较。对于暴露于炎性条件的ZNT固溶体,其结果显示出比CP Ti观察到的更好的腐蚀行为,这是形成了更具保护性的表面氧化物层的结果。 ZNT陶瓷材料的电化学结果和机械性能表明,它是需要高耐腐蚀性和耐磨性的生物医学应用的有前途的候选者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号