The growing demands of high-throughput, accurate and fast response biological or chemical sensors are driving the development of new detection technologies. This paper presents a micromechanical biosensor with capacitive read-out method. The proposed biosensor design consists of a fixed-fixed beam attached to an interdigitated capacitor. Implementation of the interdigitated capacitor design improves the sensitivity of the biosensor. The effects of the electrode thickness, length and the number of electrode fingers on the change of capacitance are investigated. The results show that the percentage change of capacitance is proportional to the number of the electrode fingers. Similarly, the increase in the length of the electrodes results in an increase in the percentage change of the capacitance. However, as the thickness of the electrode increases, the percentage change of the capacitance decreases.
机译:高通量,准确和快速响应的生物或化学传感器的需求不断增长,这推动了新检测技术的发展。本文提出了一种具有电容读出法的微机械生物传感器。所提出的生物传感器设计包括一个固定在交叉指形电容器上的固定束。叉指电容器设计的实施提高了生物传感器的灵敏度。研究了电极厚度,长度和电极指的数量对电容变化的影响。结果表明,电容的百分比变化与电极指的数量成正比。类似地,电极长度的增加导致电容的百分比变化的增加。但是,随着电极厚度的增加,电容的百分比变化减小。