The performance of water mist fire-resistant is researched by the experiments. The change of temperature, smoke flow,smoke desity (such as oxygen, carbon monoxide, nitrogen monoxide)in the test space is obtained. It that the effect of the various working pressure and water flow rate on the spread of flame and smoke is analyzed. The results show that the spread of smoke can be prevented with water mist and the effect of cool smoke is very obvious. High operating pressure help to putout the fire. After spraying water mist the burn became more incomplete with the increase of oxygen concentration and the decrease of CO2 concentration in the compartment. The conclusion of this paper is helpful to the fireproofing desing of water mist.
机译:通过实验研究了水雾耐火的性能。得到温度,烟雾,烟雾休眠(如氧气,一氧化碳,氮一氧化氮)的变化。分析了各种工作压力和水流率对火焰和烟雾蔓延的影响。结果表明,烟雾的蔓延可以用水雾预防,凉爽烟雾的效果非常明显。高效压力有助于抛火。喷洒水雾后,随着氧气浓度的增加和隔室中的CO 2浓度的降低变得更加不完整。本文的结论有助于防火防锈雾。