首页> 外文会议>Conference on biomedical applications in molecular, structural, and functional imaging >Very low-dose adult whole-body tumor imaging with F-18 FDG PET/CT
【24h】

Very low-dose adult whole-body tumor imaging with F-18 FDG PET/CT

机译:非常低剂量的成人全身肿瘤成像与F-18 FDG PET / CT

获取原文

摘要

The aim of this study was to evaluate if effective radiation dose due to PET component in adult whole-body tumor imaging with time-of-flight F-18 FDG PET/CT could be significantly reduced. We retrospectively analyzed data for 10 patients with the body mass index ranging from 25 to 50. We simulated F-18 FDG dose reduction to 25% of the ACR recommended dose via reconstruction of simulated shorter acquisition time per bed position scans from the acquired list data. F-18 FDG whole-body scans were reconstructed using time-of-flight OSEM algorithm and advanced system modeling. Two groups of images were obtained: group A with a standard dose of F-18 FDG and standard reconstruction parameters and group B with simulated 25% dose and modified reconstruction parameters, respectively. Three nuclear medicine physicians blinded to the simulated activity independently reviewed the images and compared diagnostic quality of images. Based on the input from the physicians, we selected optimal modified reconstruction parameters for group B. In so obtained images, all the lesions observed in the group A were visible in the group B. The tumor SUV values were different in the group A, as compared to group B, respectively. However, no significant differences were reported in the final interpretation of the images from A and B groups. In conclusion, for a small number of patients, we have demonstrated that F-18 FDG dose reduction to 25% of the ACR recommended dose, accompanied by appropriate modification of the reconstruction parameters provided adequate diagnostic quality of PET images acquired on time-of-flight PET/CT.
机译:本研究的目的是评估是否有效的辐射剂量,因为在成人全身肿瘤成像中具有飞行时间F-18 FDG PET / CT的PET组分,可以显着降低。我们回顾性地分析了10例体重指数的10例患者的数据,该患者的体重指数范围为25至50.通过重建每张大的列表数据的模拟较短的采集时间来模拟F-18 FDG剂量降低到ACR推荐剂量的25% 。使用飞行时间OSEM算法和高级系统建模,重建F-18 FDG全身扫描。获得两组图像:A组具有标准剂量的F-18 FDG和标准重建参数和B组,分别具有模拟的25%剂量和改性重建参数。蒙蔽了模拟活动的三个核医学医生独立地审查了图像并比较了图像的诊断质量。基于来自医生的输入,我们选择了B组的最佳改性重建参数。在所获得的图像中,在A组中观察到的所有病变在B组中可见。肿瘤SUV值在A组中不同,如与B组相比。然而,在A和B组的图像的最终解释中没有报告显着差异。总之,对于少数患者,我们已经证明,F-18 FDG剂量降低到ACR推荐剂量的25%,并伴随着重建参数的适当修改,提供了在时间内获得的宠物图像的充分诊断质量。飞行PET / CT。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号