首页> 外文会议>2011 International Conference on Computer Distributed Control and Intelligent Environmental Monitoring >Modeling and Analysis of the Effect Mechanism of Glass Sun-Shading on Building Cooling Energy Efficiency in Guangzhou
【24h】

Modeling and Analysis of the Effect Mechanism of Glass Sun-Shading on Building Cooling Energy Efficiency in Guangzhou

机译:广州市玻璃遮阳对建筑制冷节能的影响机理建模与分析

获取原文

摘要

Based on the modeling and analysis of the glass sun-shading mechanism the hourly building cooling energy consumption of an office building in Guangzhou was calculated for different building glass with various inferred transmitted rates. The results showed that the glass sun shading coefficient and the building cooling energy could be significantly reduced by decreasing the inferred transmitted rate of the glass for the constant visual light transmitted rate of0.6. The sun-shading coefficient of the glass could be significantly reduced from 0.856 to 0.363 as the inferred transmitted rate was decreased from 1.0 to 0.0. As the inferred transmitted rate of the building glass was decreased from 1.0to 0.4 and 0.0, the building cooling energy could be reduced by efficiency coefficients were 13.7% and 23.3%, respectively. The findings that the significant energy efficiency could be obtained through decreasing the inferred transmitted rate at the constant visual light transmitted rate provide a useful guidance to the design of the functional building glass and the building energy efficiency.
机译:通过对玻璃遮阳机理的建模和分析,计算出了广州市某办公楼建筑物每小时的建筑能耗,并推算出不同的透射率。结果表明,在恒定的0.6可见光透过率下,通过降低玻璃的推断透过率,可以显着降低玻璃遮阳系数和建筑物的冷却能。当推断的透射率从1.0降低到0.0时,玻璃的遮阳系数可以从0.856显着降低到0.363。随着推断的建筑玻璃透射率从1.0降低到0.4和0.0,可以将建筑冷却能降低,效率系数分别为13.7%和23.3%。通过以恒定的可见光透射率降低推断的透射率可以获得显着的能量效率的发现,为功能性建筑玻璃的设计和建筑物的能量效率提供了有用的指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号