The GEMINI TF PET-MRI (Philips Healthcare, Cleveland, OH) is a newly released whole body hybrid imaging system with a Philips Achieva 3T system and a Philips TF (TruFlight) PET. We report the standard NEMA NU2 measurements for the scanner. Compared to PET-CT, modifications to the PET were made to avoid mutual system interference and deliver uncompromising performance which is equivalent to the standalone systems. The PET gantry was redesigned to introduce magnetic shielding for the PMTs. Stringent electromagnetic noise requirements of the MR system necessitated the removal of PET gantry electronics to be housed in the PET-MR equipment room. All PET calibrations and measurements were done with the MRI ramped to 3T, shimmed and calibrated. Measurements were performed as described in NEMA standard manual. GEMINI TF PET-CT typical NEMA values were compared to PET-MR (n≥4 for PET-MR data). Spatial resolution and sensitivity were comparable to PET-CT results. Timing resolution and energy resolution of the PET-MR system (not NEMA standard measurements) were measured to be 520 ps and 12%, respectively. Image quality measurements performed with IEC phantom yielded results comparable to PET-CT. The NEMA results obtained with PET-MR are equivalent to typical GEMINI TF PET-CT results. System energy and timing resolution were comparable to PET-CT demonstrating the effect of magnetic shielding to maintain the PMTs in normal flux levels. In conclusion, we report the design of a whole-body hybrid PET-MRI system where PET performance is comparable to standalone GEMINI TF PET-CT system.
机译:GEMINI TF PET-MRI(飞利浦医疗保健公司,俄亥俄州克利夫兰)是一种新近发布的全身混合成像系统,配有Philips Achieva 3T系统和Philips TF(TruFlight)PET。我们报告扫描仪的标准NEMA NU2测量值。与PET-CT相比,对PET进行了修改,以避免了相互之间的系统干扰,并提供了与独立系统相当的出色性能。 PET龙门经过重新设计,为PMT引入了磁屏蔽。由于MR系统对电磁噪声的严格要求,因此有必要拆除要容纳在PET-MR设备室中的PET龙门电子设备。所有PET校准和测量都是在MRI升至3T,匀场和校准后进行的。如NEMA标准手册中所述进行测量。将GEMINI TF PET-CT的典型NEMA值与PET-MR进行比较(对于PET-MR数据,n≥4)。空间分辨率和灵敏度与PET-CT结果相当。 PET-MR系统的定时分辨率和能量分辨率(不是NEMA标准测量值)分别为520 ps和12%。使用IEC幻象进行的图像质量测量得出的结果可与PET-CT媲美。用PET-MR获得的NEMA结果与典型的GEMINI TF PET-CT结果相当。系统能量和时序分辨率与PET-CT相当,证明了磁屏蔽可将PMT保持在正常的通量水平。总之,我们报告了一种全身混合PET-MRI系统的设计,其PET性能可与独立的GEMINI TF PET-CT系统相媲美。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号