首页> 外文会议>ASME InterPack conference;IPACK2009 >EFFECTIVE THERMAL MANAGEMENT OF DATA CENTERS USING EFFICIENT CABINET DESIGNS
【24h】

EFFECTIVE THERMAL MANAGEMENT OF DATA CENTERS USING EFFICIENT CABINET DESIGNS

机译:使用高效的机柜设计对数据中心进行有效的热管理

获取原文

摘要

Rising heat load trends in data center facilities have raised concerns over energy usage. The environmental protection agency has reported that the energy used in 2006 by data center industry was 1.5% of the total energy usage by entire nation. The experts agree that by year 2010, this usage will approach 2% of the annual energy use nationwide. Although many new concepts such as airside economizers and cogeneration are gaining traction, many data center facilities spend considerable energy in cooling. In this study, various cabinet designs are discussed. Isolating the supplied cold air from hot exhaust air is always a challenge in thermal management of data center facilities. A cabinet design that employs chimney to aid the isolation of hot and cold air is discussed. A computational model of representative data center is created to study the effectiveness of design under various supply air fractions.
机译:数据中心设施中不断增加的热负荷趋势引起了人们对能源使用的担忧。环境保护机构报告说,数据中心行业在2006年使用的能源占全国能源总使用量的1.5%。专家们一致认为,到2010年,这种使用量将接近全国每年能源使用量的2%。尽管许多新概念(例如,空侧节能器和热电联产)越来越受到人们的关注,但许多数据中心设施在冷却方面花费了相当多的精力。在这项研究中,讨论了各种机柜设计。将提供的冷空气与热排气隔离开来,始终是数据中心设施热管理中的一个挑战。讨论了一种采用烟囱来帮助隔离热空气和冷空气的机柜设计。创建了代表性数据中心的计算模型,以研究在各种送风分数下的设计有效性。