首页> 外文会议>2010 IEEE Nanotechnology Materials and Devices Conference >Development of readout system for carbon nanotube based infrared detector
【24h】

Development of readout system for carbon nanotube based infrared detector

机译:基于碳纳米管的红外探测器读出系统的研制

获取原文

摘要

The emergence of carbon nanotube (CNT) based infrared (IR) detectors has welcomed new opportunities for IR detection for both military and civil applications. This led to research and development of high resolution CNT based IR imaging systems. In this paper, a differential input charge integrator current amplifier was designed to read the photocurrent of CNT based IR detectors. Also, all parts, including readout chip (ROIC), data acquisition card (DAQ card) and PC display, were discussed. With this technology, CNT based IR detector worked in zero bias by the differential input. Meanwhile, experiment tests on the CNT based IR sensors have shown that the least current being detected can reach to 20 pA in this readout system.
机译:基于碳纳米管(CNT)的红外(IR)检测器的出现为军事和民用红外检测提供了新的机遇。这导致了基于高分辨率CNT的IR成像系统的研究和开发。本文设计了一种差分输入电荷积分器电流放大器,以读取基于CNT的红外探测器的光电流。此外,还讨论了所有部件,包括读出芯片(ROIC),数据采集卡(DAQ卡)和PC显示器。借助这项技术,基于CNT的IR检测器通过差分输入在零偏压下工作。同时,对基于CNT的红外传感器的实验测试表明,在此读出系统中,被检测到的最小电流可以达到20 pA。