In order to investigate the hemodynamic effect of intervention for intracranial serial saccular aneurysm treated with semi-circular section stent, four finite element models of serial saccular aneurysms were constructed, one model without stent intervention (U-type) and three models with bare stent intervention. These stents include one with circular section (C-type), one with semi-circular section whose circular arch faces towards the aneurismal cavity (ES-type) and one with semi-circular section whose circular arch faces towards the vascular center (IS-type). Computational fluid dynamics simulations of physiologically pulsatile blood flow in these models were performed. Velocity of blood flow in stented models were effectively weakened, and velocity near aneurismal wall was very low. Impact of blood flow on aneurysm was weakened because of stent intervention. Magnitude and fluctuation of wall shear stress were reduced, and the distribution of wall shear stress was more balanced. Pressure in aneurysm was almost not changed, and the pressure of stented models was slightly increased. Comparison analysis of the two aneurismal cavities demonstrated that the flow and wall shear stress were basically same, and the pressure of the distal cavity was lower than the proximal one. These results could provide some theoretical guidance to structural design of endovascular stent.
机译:为了研究半圆形截面支架治疗颅内连续囊状动脉瘤的介入治疗的血流动力学效应,构建了四个连续性囊状动脉瘤的有限元模型,一种是不进行支架干预的模型(U型),三种是裸眼支架干预的模型。 。这些支架包括一个具有圆形截面的支架(C型),一个具有半圆形截面的支架,其圆拱朝向动脉瘤腔(ES型),以及一个具有半圆形截面的支架,其圆拱朝向血管中心(IS-类型)。在这些模型中进行了生理性脉动血流的计算流体动力学模拟。支架模型中的血流速度被有效减弱,动脉瘤壁附近的速度非常低。由于支架的介入,血流对动脉瘤的影响减弱了。减小了墙体剪应力的大小和波动,墙体剪应力的分布更加平衡。动脉瘤中的压力几乎没有变化,而置入支架的模型中的压力略有增加。两种动脉瘤腔的比较分析表明,流动和壁切应力基本相同,远端腔的压力低于近端腔的压力。这些结果可为血管内支架的结构设计提供一些理论指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号