首页> 外文会议> >Acoustic monitoring of insulation delaminations during thermal cycling tests on a stator bar
【24h】

Acoustic monitoring of insulation delaminations during thermal cycling tests on a stator bar

机译:在定子棒上进行热循环测试期间,对绝缘层的声学监测

获取原文

摘要

This paper describes a novel acoustic monitoring technique of insulation delaminations during a thermal cycling test (TC) on a stator bar. Acoustic signals emitted from insulation delaminations within the stator bar were continuously recorded during a TC test. An increase in measured acoustic signals indicates insulation delaminations within the stator bar under test. Dissipation factor tests, partial discharge tests, tap tests, and dissections were performed. Those diagnostic test results were compared with the acoustic test data to verify insulation delaminations. The acoustic monitoring system can indicate which cycle insulation delaminations occurred and when they occurred in a given thermal cycle during a TC test.
机译:本文介绍了定子杆上热循环试验(TC)期间绝缘分层的新型声学监测技术。在TC测试期间连续记录从定子条内的绝缘分层发射的声学信号。测量声信号的增加表示被测定子条内的绝缘分层。进行耗散因子测试,局部放电测试,敲击试验和解剖。将这些诊断测试结果与声学测试数据进行比较,以验证绝缘分层。声学监测系统可以指示发生了哪些循环绝缘分层,并且在TC测试期间发生在给定的热循环中。

著录项