Effect of the Frost on the Thermal Performance of the Evaporator for the Residential Heat Pump

机译:霜冻对住宅热泵蒸发器热性能的影响

获取原文

摘要

The present study investigated the performance of the evaporator for the residential heat pump under frosting condition. The size of all evaporators was 400 × 250 × 12.7 mm (W × H × D). Key experimental parameters were fin type (plate and slit fin), fin pitch (1.3, 1.4 and 1.5 mm), the face velocity of air (0.5, 1.0, 1.5 and 2.0m/s), and the number of row (1 and 2) of the heat exchanger. The ethylene glycol-water mixture was used as a refrigerant. The test was done in a phychrometric calorimeter chamber.The air side pressure drop and heat transfer rate were measured as frost grew. The pressure drop of the evaporator under frosting with the slit fin was higher than that with the plate fin. It increased as the number of rows increased, the fin pitch decreased, and the air velocity decreased for the slit fin. The heat transfer rate of the evaporator under frosting with the slit fin was higher than that with the plate fin. It increased as the air velocity increased even though it was not much affected by the other parameters for the slit fin. The EF decreased as frost grew to be lower than one. The HGR decreased to be lower than one as frost grew. It decreased as the number of row increased.
机译:本研究调查了结霜条件下住宅用热泵蒸发器的性能。所有蒸发器的尺寸均为400×250×12.7 mm(W×H×D)。关键实验参数为鳍片类型(板翅片和狭缝鳍片),鳍片间距(1.3、1.4和1.5 mm),空气面速度(0.5、1.0、1.5和2.0m / s)以及行数(1和1)。 2)的换热器。乙二醇-水混合物用作制冷剂。该测试在荧光量热室中进行。 随着霜的生长,测量空气侧压降和传热速率。狭缝翅片结霜时蒸发器的压降高于板翅片。它随着行数的增加而增加,翅片间距减小,而狭缝翅片的空气速度降低。狭缝翅片结霜时蒸发器的传热速率高于板翅片。尽管它不受狭缝鳍的其他参数的影响很大,但随着风速的增加而增加。当霜冻低于1时,EF降低。随着霜冻的增加,HGR降低到低于1。随着行数的增加,它减少了。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号