This paper describes the conceptual thermo-mechanical design of the MIXS (Mercury Imaging X-ray Spectrometer) Focal Plane Assembly (FPA). This design is mainly driven by thermal requirements: The Detector is required to operate below -45 °C, while the Detector and proximity electronics dissipate more than 2 W, which the passive cooling system can not handle at the required temperature. In order to get rid of this cross-constraint, the Detector was separated from the Proximity electronics board, which in turn has introduced a new dimension of mechanical requirements, as the 370+ bond wires that interconnect both are extremely delicate and have a high thermal conductivity.
机译:本文介绍了MIXS(水星成像X射线光谱仪)焦平面组件(FPA)的概念热机械设计。此设计主要由热量要求决定:检测器要求在-45°C以下工作,而检测器和邻近电子设备的耗散功率超过2 W,被动冷却系统无法在所需温度下进行处理。为了消除这种交叉约束,将检测器与邻近电子电路板分开,后者又引入了新的机械要求维度,因为互连的370+键合引线非常精细且具有很高的散热性。电导率。