【24h】

SAFETY EVALUATION AND DYNAMIC COUPLING ANALYSIS OF COUNTER-ARCHED SLAB IN PLUNGE POOL

机译:蓄水池沉拱板的安全性评估和动力耦合分析

获取原文

摘要

The stability of plunge pool slab of hydropower station is crucial to energy dissipation, but the working conditions of counter-arched slab is very complex and its stress procedure is considerably nonlinear and coupling. Therefore, a nonlinear dynamic coupling method to analysis the counter-arched slab configuration is put forward, which can reflect the coupling of dynamic loads, slab, anchor bars, groundwork and abutment as well as the dynamic procedure of instability. Various nonlinear factors and static-dynamic coupling are taken into consideration, and the working conditions, stress mechanism, dynamic instability procedure and influential instability factors are revealed. The proposed method thus provides a more comprehensive safety evaluation method of plunge pool, which further provides an important theoretical basis for engineering design of counter-arched slab in plunge pool.
机译:水电站跳水池板的稳定性对能量耗散至关重要,但反拱板的工作条件非常复杂,其应力过程具有很大的非线性和耦合性。因此,提出了一种非线性的动力耦合方法来分析平板的反拱结构,它可以反映动载荷,板,锚杆,地基和支座的耦合以及失稳的动态过程。考虑了各种非线性因素和静动力耦合,揭示了工作条件,应力机理,动态失稳过程和影响性失稳因素。所提出的方法为跳水池的安全性评价提供了更为全面的方法,为跳水池反拱板的工程设计提供了重要的理论依据。

著录项