BIOMECHANICAL EVALUATION OF A WIDE-DIAMETER SHORT DENTAL IMPLANT FOR USE IN COMPROMISED BONE QUALITY REGIONS BY FINITE ELEMENT METHOD

机译:有限元法评估全骨质疏松区域的短径牙科种植体的生物力学评价

获取原文

摘要

The success rates of dental implant treatments in posterior mandible and maxilla could be compromised due to the increased masticatory forces and poor bone quality. In addition, the length of the implant is limited by maxillary sinus and mandibular canal in these regions. Wide-diameter short (WDS) implants provide a good alternative to increase the stability and the reliability of the implants in such conditions. The objective of this study is to evaluate the biomechanical properties of a wide implant by performing finite element analyses (FEA). Comparison of the strain distribution induced in the bone by a WDS implant and by a narrow-diameter long (NDL) implant, in clinical scenarios exhibiting different amounts of crestal bone, and under varying insertion depths demonstrated that WDS implant can be used safely and should perform as well as its NDL counterpart.
机译:由于咀嚼力的增加和骨骼质量的下降,可能会影响下颌骨和上颌后牙种植体治疗的成功率。另外,在这些区域中,植入物的长度受到上颌窦和下颌管的限制。在这种情况下,宽直径短(WDS)植入物提供了一种很好的选择,可以提高植入物的稳定性和可靠性。这项研究的目的是通过执行有限元分析(FEA)来评估宽植入物的生物力学性能。 WDS植入物和窄直径长(NDL)植入物在临床情况下表现出不同的牙槽骨量以及在不同的插入深度下,在骨骼中引起的应变分布比较表明,WDS植入物可以安全使用,并且应该与NDL的性能一样好。