This paper briefly describes the principle of voltage regulation of 220kV transformer, discusses the influence of selection of rated voltage on medium and low voltage side of transformer, discusses the reasons for the contradiction of voltage adjustment on the medium and low side of transformer, and puts forward several solutions to the voltage adjustment with a concrete example, which has some reference significance in power grid operation and 220kV substation design.
机译:本文简要介绍了220kV变压器电压调节原理,讨论了变压器介质和低压侧的额定电压选择的影响,讨论了变压器介质和低端电压调节矛盾的原因将多个解决方案转发到电压调节与一个具体示例,在电网运行和220kV变电站设计中具有一些参考意义。