Faulty phase selection is one of the core technologies of full compensation arc suppression system for single-phase grounding faults in distribution networks. At present, faulty phase selection is mainly used for single-phase automatic reclosing and distance protection algorithms in direct-earthing systems. These methods have applicability problems in single-phase-to earth faults in non-effectively grounded distribution networks because of different neutral voltage. when the theoretical current is injected, whose value is determined by the full compensation arc supperssion method, voltage of the healthy phase, which is the miss-selected phase, will approach to a non-zero certain value as transition resistance increases; if the phase is selected correctly, when the corresponding current is injected, the selected phase voltage will be close to 0. This feature is used to distinguish the faulty phase, and thus promoting the full compensation arc suppression technology used in distribution networks.
机译:故障相位选择是用于分销网络中单相接机故障的全级补偿弧抑制系统的核心技术之一。目前,故障相位选择主要用于直接接地系统中的单相自动闭合和距离保护算法。由于中性电压不同,这些方法具有在非有效接地的分配网络中的单相到接地故障的适用性问题。当注射理论电流时,其值由完全补偿弧壳化方法确定,健康相的电压是错过选择的阶段,将接近非零一定值作为过渡电阻增加;如果正确选择相位,当注入相应的电流时,所选择的相电压将接近0.该特征用于区分故障相位,从而促进分配网络中使用的完整补偿弧抑制技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号