首页> 外文会议>Electromagnetic Compatibility, 2006. EMC-Zurich 2006. 17th International Zurich Symposium on >Simulation and measurement of the transient field of indirect electrostatic discharge
【24h】

Simulation and measurement of the transient field of indirect electrostatic discharge

机译:间接静电放电瞬态场的仿真与测量

获取原文

摘要

The transient near-field of the electrostatic discharge (ESD) is a kind of high power transient phenomenon, which strongly affects the operation of the electronic devices. In this paper, the transient field of the indirect electrostatic discharge through the vertical coupling plane (VCP) is numerically simulated by using the FDTD method with the PML. The configuration of the current source is considered carefully. The simulation results on different positions show different transient effects. The simulated data are compared with those measured by an optic testing system
机译:静电放电(ESD)的瞬态近场是一种高功率瞬态现象,严重影响电子设备的运行。本文利用FDTD方法和PML对通过垂直耦合平面(VCP)的间接静电放电的瞬态场进行了数值模拟。仔细考虑电流源的配置。在不同位置上的仿真结果显示出不同的瞬态效应。将模拟数据与光学测试系统测得的数据进行比较

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号