摘要

This study was performed for a purpose of developing a passive sampler, which can quantify formaldehyde in indoor air by sampling for about 1 hour. The method to investigate this time is a one to measure the fluorescence of s-triazolo[3,4-a]-phthalazine which comes from the reaction of 1-hydrazinophthalazineand formaldehyde by High Performance Liquid Chromatograph with fluorescence detector.A passive sampler to be made is the fillng of alkali-impregnated silica gel of 0.8g into a porous tube made of polytetrafluoroethylene resin.The uptake rate of the passive sampler is 3.06 μg/ppm/hr, which is equivalent to 42ml/min of sampling rate of a pump method. The repeatability of the passive sampler is 6.9 % in coefficient of variation. The minimum measuring limit is 10 ppb of formaldehyde with 1 hour sampling. It has been recognized that the measured value of present method and DNPH pump method (2,4-dinitrophenylhydrazine active sampler method) has a significant correlation.
机译:进行这项研究的目的是开发一种被动采样器,该采样器可以通过采样约1小时来量化室内空气中的甲醛。这次研究的方法是一种通过高效液相色谱仪和荧光检测器测量1-肼基酞嗪与甲醛反应产生的s-三唑并[3,4-a]-酞嗪的荧光的方法。 待制作的无源采样器是将0.8g的碱浸硅胶填充到由聚四氟乙烯树脂制成的多孔管中。 无源采样器的吸收速率为3.06μg/ ppm / hr,相当于泵方法的采样速率为42ml / min。无源采样器的重复性变异系数为6.9%。最低测量限为10 ppb甲醛,采样时间为1小时。已经认识到,本方法的测量值与DNPH泵方法(2,4-二硝基苯肼活性取样器方法)具有显着的相关性。