A method was developed and tested to characterize the gas-phase boundary layer developing on the surface of seven indoor materials from formaldehyde emission measurements carried out under environmental chamber conditions using passive flux samplers having different diffusion lengths. This indirect approach consistently provides many assessed values of gas-phase boundary layer thickness with a mean and range of 31.6 ± 17.4 mm. These experiments also yield other information like the gas concentration on the material surface as well as the concentration gradient inside the gas-phase boundary layer. Linear relationships were found between formaldehyde gas concentration on the material surface, the concentration gradient inside the gas-phase boundary layer and the emission rate. Data and relationships should be useful for parameterizing and modeling formaldehyde emissions from indoor surfaces.
机译:通过使用具有不同扩散长度的无源通量采样器,在环境室条件下进行的甲醛释放量测量中,开发并测试了一种方法来表征七种室内材料表面上形成的气相边界层的特征。这种间接方法始终提供气相边界层厚度的许多评估值,平均值和范围为31.6±17.4 mm。这些实验还产生其他信息,例如材料表面上的气体浓度以及气相边界层内部的浓度梯度。发现材料表面上的甲醛气体浓度,气相边界层内部的浓度梯度与排放速率之间存在线性关系。数据和关系对于参数化和模拟室内表面甲醛排放量应该是有用的。

著录项

  • 来源
    《Building and Environment》 |2014年第3期|249-255|共7页
  • 作者单位

    Universite Lille Nord de France, F-59000 Lille, France,Ecole des Mines de Douai, Departement Chimie et Environnement, 941 rue Charles Bourseul, BP 10838, 59508 Douai Cedex, France,Pole RIME C2MA, Ecole des Mines d'Ales, Helioparc, 2 Avenue Pierre Angot, 64053 Pau Cedex 9, France;

    Universite Lille Nord de France, F-59000 Lille, France,Ecole des Mines de Douai, Departement Chimie et Environnement, 941 rue Charles Bourseul, BP 10838, 59508 Douai Cedex, France;

    Pole RIME C2MA, Ecole des Mines d'Ales, Helioparc, 2 Avenue Pierre Angot, 64053 Pau Cedex 9, France;

    Laboratoire Thermique Energetique et Precedes, Universite de Pau et des Pays de I'Adour, BP, Pau 7511-64075, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Boundary layer; Indoor material; Emission; Indoor air quality; Formaldehyde;