In this study microtremor measurements were conducted within the period from February to December, 2007 at the Kyushu University Hospital South Building. Firstly, we compared the spectral ratio results of this study with the past measurement results (Mori and Kawase, 2001) and it can be concluded that the construction of the North building and (or) reinforced lead dampers (after West off Fukuoka Earthquake) caused 8.2% are changed the natural frequencies from 0.97Hz to 1.05Hz in the EW direction. Secondly, we correlated spectral ratio results with the pit level temperature records. The spectral ratios of basement floor-pit level (BP) are influenced by temperature variation, i.e., when temperature increases the spectral ratio values decreases.
机译:在本研究中,MicroRemor测量是在2007年2月至12月在九州大学医院南部建筑的期间进行的。首先,我们将本研究的光谱比率与过去的测量结果(Mori和Kawase,2001)进行了比较,可以得出结论,北建筑和(或)钢筋铅阻尼器(福冈地震后的西部)造成的建设8.2%在EW方向上改变0.97Hz至1.05Hz的自然频率。其次,我们与坑级温度记录相关的光谱比率。基底底坑液位(BP)的光谱比受温度变化的影响,即,当温度增加光谱比值时。