The amount of heat power delivered to contacts as the result of electric arc ignition before metallic touching of contacts depends on electric circuit parameters, as well as on the size and velocity of change of the contact gap. The make arc duration depends hence on the value of the intensity of electric field in the contact area, and on the velocity of contacts closing. In general, the higher the value of velocity of contact closing in an electric switch, the shorter the turn-on time. Resulting is shorter time of arc duration that enhances a longer life of the electric switch. High velocity has a negative aspect as it causes rebounding of contacts. The paper describes the problems of calculation the arc switching time in contact switches during making of a current in current paths and test circuits.
机译:在触点金属接触之前,由于电弧点火而产生的传递给触点的热量取决于电路参数,以及触点间隙变化的大小和速度。因此,产生电弧的持续时间取决于接触区域中电场强度的值以及触点闭合的速度。通常,电气开关中的触点闭合速度值越高,接通时间越短。结果是电弧持续时间缩短,从而延长了电开关的使用寿命。高速会带来负面影响,因为它会引起触点反弹。本文描述了在电流路径和测试电路中产生电流时,计算接触开关中电弧开关时间的问题。