EFFECT OF SECONDARY FLOW ON HEAT TRANSFER OVER A GUIDE VANE SUCTION SIDE

机译:二次流动对导流吸气侧传热的影响

获取原文

摘要

An accurate design of a guide vane has become a major issue in gas turbine engineering since secondary flow in vane cascade has a significant effect on the end wall and airfoil suction surfaces. Heat transfer and average flow measurements were performed in a linear guide vane cascade consisting of five gas turbine vanes. All measurements were taken on the suction surface of the middle (third) airfoil. The height-to-pitch ratio H/S was varied from 1.0 to 0.17, the inlet boundary layer thickness 腳(in) was either 2 mm or 10 mm. The vortex structures influence the average flow parameters, the laminar-to-turbulence transition, and the local heat transfer. This is especially pronounced in the area close to the end wall area. The inlet flow temperature non-uniformity has no influence on the heat transfer, however local flow temperature 'spikes' were registered at x-bar = 0.6 due to the flow enthalpy migration in the span-wise direction. A few useful correlations are suggested as a result of the experimental data processing.
机译:导流叶片的精确设计已成为燃气轮机工程中的主要问题,因为导叶栅中的二次流对端壁和翼型吸力表面有重大影响。传热和平均流量的测量是在由五个燃气轮机叶片组成的线性导向叶片级联中进行的。所有测量均在中(第三)翼型的吸力表面上进行。高度/间距比H / S从1.0更改为0.17,入口边界层厚度脚(in)为2 mm或10 mm。涡旋结构会影响平均流量参数,层流到湍流的过渡以及局部传热。这在靠近端壁区域的区域中尤其明显。入口流动温度的不均匀性对传热没有影响,但是由于流动焓在跨度方向上的迁移,导致局部流动温度“峰值”记录在x-bar = 0.6处。作为实验数据处理的结果,提出了一些有用的相关性。