Long power cables and large machines require different application techniques from most electrical wiring. Selection of conductor size must consider insulation temperature as well as voltage drop. The NEC is commonly used for determining conductor size. It is primarily based on current carrying capacity, since this impacts the temperature of the insulation. However, operational considerations demand the consideration of other factors. The procedure is primarily a mathematical design practice that is seldom considered in manual calculations. We have applied numerous considerations to develop a simple relationship that can be readily applied in routine designing. It incorporates wire diameter, length, current, number of phases, and temperature correction, with permissible voltage drop.
机译:长电缆和大型机器需要与大多数电线不同的应用技术。导体尺寸的选择必须考虑绝缘温度以及电压降。 NEC通常用于确定导体尺寸。它主要基于载流量,因为这会影响绝缘的温度。但是,操作上的考虑需要考虑其他因素。该过程主要是数学设计实践,很少在手动计算中考虑。我们已经应用了许多考虑因素来开发一种简单的关系,该关系可以很容易地应用于常规设计中。它包括导线直径,长度,电流,相数和温度校正,并允许压降。