Quantitative measurement of calcium transients in perfused mouse heart using Rhod-2 fluorometry

机译:使用Rhod-2荧光定量测定灌注小鼠心脏中钙的瞬变

获取原文

摘要

Abstract: We present a technique for optical detection of calcium transients in perfused mouse heart labeled with the calcium sensitive fluorescent dye Rhod-2. The isolated mouse-heart is placed in a water-jacketed chamber at 37 degrees Celsius, and is stimulated at 8 Hz, with 100 $mu@g of Rhod-2 bolused through the perfusate. After a 25-minute washout period, approximately 6 fold increase in fluorescence above background can be detected spectrofluorimetrically at 589 nm when excited at 524 nm. Both of these wavelengths are isobestic with regard to O$-2$/, thus minimizing interference due to changes in tissue oxygenation. Ca$+2$PLU$/-dependent fluorescence transients are measured, as well as the corresponding left ventricular pressure signal. Our calcium transient signals represent 33 plus or minus 9% of diastolic fluorescence intensity. As the fluorescence emission is attenuated with the washout of Rhod-2 through the perfusate, the reflected absorbance between 524 nm (Rhod-2 sensitive) and 589 nm (Rhod- 2 insensitive) is used as a measure of dye concentration in tissue. The fluorescence-to-absorbance ratio measured from the perfused heart is verified to be insensitive to dye concentration, and thus can be used to determine the calcium concentration of the heart. Maximal calcium dependent fluorescence is calibrated in situ using high calcium and a SR Ca-ATP$-ase$/ inhibitor to tetanize the heart. The calculated cytosolic calcium concentrations for perfused mouse heart are 368 plus or minus 68 nM and 654 plus or minus 164 nM in diastole and systole, respectively. An effective method of minimizing changes in tissue scattering in the calcium quantification is also discussed. !7
机译:摘要:我们提出了一种光学检测钙敏感荧光染料Rhod-2标记的灌注小鼠心脏中钙瞬变的技术。离体的小鼠心脏被置于摄氏37度的水套腔中,并以8 Hz的频率被刺激,通过灌注液注入100μg的Rhod-2。经过25分钟的洗脱期后,当在524 nm处激发时,可以在589 nm处用分光荧光法检测到比背景高出约6倍的荧光。这两个波长对于O $ -2 $ /都是等规的,因此将由于组织氧合作用的变化引起的干扰最小化。测量Ca + 2 $ PLU $ /依赖性的荧光瞬变,以及相应的左心室压力信号。我们的钙瞬变信号代表舒张期荧光强度的33%或负9%。由于通过灌注液冲洗Rhod-2会减弱荧光发射,因此将524 nm(Rhod-2敏感)和589 nm(Rhod-2不敏感)之间的反射吸光度用作组织中染料浓度的量度。验证了从灌注心脏测得的荧光吸收率对染料浓度不敏感,因此可用于确定心脏的钙浓度。使用高钙和SR Ca-ATP $ ase $ /抑制剂在原位校准最大钙依赖性荧光,以使心脏僵化。灌注的小鼠心脏的舒张期和收缩期的胞质钙浓度计算值分别为368正负68 nM和654正负164 nM。还讨论了在钙定量中最小化组织散射变化的有效方法。 !7

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号