This paper presents ozone removal efficiencies, measured over an extended period of time, inthree different settings: a test plenum, an air handler providing outdoor air to a Class 100cleanroom, and a plenum downstream of an air handler providing outside air to a second, smallerClass 100 cleanroom. In each of these settings, the initial ozone-removal efficiencies werecomparable. After 8 years of service, the charcoal fiiters servicing the first cleanroom wereremoving about 6070 of the ozone in the airstream. After 7 years of service, the charcoal filtersservicing the second cleanroom were removing 70% of the ozone in the airstream. After 5 yearsof continuous operation, the charcoal filters in the test plenum were removing more than 90% ofthe ozone in the airstream. These restits indicate that adequately sized charcoal filters have verylong service-lives for ozone removal, provided their active sites are not compromised byaccumulated sub-micron particles.
机译:本文介绍了在较长时间范围内测得的臭氧去除效率。 三种不同的设置:测试气室,向室外空气提供Class 100的空气处理器 洁净室和空气处理器下游的通风间,向第二个较小的外部空气提供外部空气 100级无尘室。在每种情况下,最初的臭氧去除效率均为 可比。经过8年的服务,为第一个无尘室服务的木炭过滤器 去除气流中约6070的臭氧。使用7年后,木炭过滤器 为第二个洁净室维修时,去除了气流中70%的臭氧。 5年后 在连续运行的过程中,测试气室中的木炭过滤器去除了90%以上的 气流中的臭氧。这些还原表明适当尺寸的木炭过滤器具有 去除臭氧的使用寿命长,前提是其活动场所不会受到臭氧的损害 累积的亚微米颗粒。