This paper proposes an equivalent circuit analysis to suppress overvoltage and ringing in PWM inverter-fed AC motor drive systems where long motor leads are required. Conventional analysis of the phenomenon is based on voltage reflection theory for the terminal end of the long cable. The authors implemented another analytical method using equivalent lumped L and C of the cable, and a transfer function for the equivalent circuit with a simple damping circuit. C-R or L-R damping circuit constants are determined from the nonoscillatory condition of the transfer-function. Digital simulations and experiments are used to verify that a simple damping circuit can satisfactorily suppress overvoltage and ringing in drive system with a long cable such as a 100 m cable.
机译:本文提出了等效电路分析,以抑制需要长电机引线的PWM逆变器馈电AC电机驱动系统中的过电压和振铃。对这种现象的常规分析是基于长电缆终端的电压反射理论。作者实现了另一种分析方法,即使用电缆的等效集总L和C,以及具有简单阻尼电路的等效电路的传递函数。 C-R或L-R阻尼电路常数由传递函数的非振荡条件确定。使用数字仿真和实验来验证,简单的阻尼电路可以令人满意地抑制长电缆(例如100 m电缆)的驱动系统中的过电压和振铃。