首页> 外文会议>Integrated Power Packaging, 1998. IWIPP. Proceedings., IEEE International Workshop on >Integral liquid cooled (ILC) high power module for efficient heat extraction
【24h】

Integral liquid cooled (ILC) high power module for efficient heat extraction

机译:集成液冷(ILC)大功率模块,可高效排热

获取原文

摘要

This paper describes an innovative method for the removal of heat from semiconductor power modules operating with high power losses. In linear applications, for example, losses are often so high that air cooling is inadequate and liquid cooling must be used. Traditionally, this is achieved by bolting a standard module onto a liquid-cooled heat exchanger. While more effective than air cooling, a thermal barrier still exists between the module base plate and separate heat sink and this contributes significantly to the total junction to ambient thermal resistance. To eliminate this barrier, APT Europe has engineered an integral liquid cooled (ILC) power module package, where the module base plate doubles as the liquid cooled heat exchanger's upper lid. In this way the cooling medium is in direct contact with the module base plate and there is no interface. To illustrate the dramatic improvement in performance made possible by this approach, the thermal performance of a dual 200 V, 7 mohm MOSFET module operating in linear mode is analysed. A detailed description of the ILC construction as well as the influence of flow rate on thermal resistance are presented.
机译:本文介绍了一种创新的方法,用于从功率损耗较高的半导体功率模块中散热。例如,在线性应用中,损耗通常很高,以致于空气冷却不足,必须使用液体冷却。传统上,这是通过将标准模块用螺栓固定到液冷热交换器上来实现的。虽然比空气冷却更有效,但在模块底板和独立的散热器之间仍然存在热障,这对与环境热阻的总结点有很大贡献。为了消除这一障碍,APT欧洲公司设计了一个整体式液冷(ILC)功率模块组件,该组件的底板加倍用作液冷热交换器的上盖。这样,冷却介质与模块基板直接接触,并且没有接口。为了说明这种方法所带来的性能上的显着改善,分析了线性模式下工作的200 V,7 mohm双路MOSFET模块的热性能。介绍了ILC构造的详细说明以及流速对热阻的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号