摘要

The reliability of a real time unsteady pressure measurement system is of great interest in many domains of industry and research. Experimental constraints often implies the presence of a pneumatic line between the pressure tap and the transducer, which causes an amplitude and a phase distortion of the pressure signal to be measured. Different ways for correction of this resonance phenomenon are proposed in the literature: analogical (active filters), numerical (inverse transfer function), or mechanical (reduction of the tube section on a certain length (restrictor). We stduied this last mechanical correction method that is generally emirically used, without any a priori suitable choice of the position or the geometry of the restrictor.
机译:实时非稳态压力测量系统的可靠性在工业和研究的许多领域中都引起了极大的兴趣。实验上的限制通常意味着在压力抽头和换能器之间存在气动管路,这会导致要测量的压力信号的幅度和相位失真。文献中提出了不同的校正共振现象的方法:类比(有源滤波器),数值(逆传递函数)或机械方法(将管段缩小一定长度(限流器))。是通常emirically使用,而不位置的任何先验合适的选择或限流器的几何形状。