【24h】

Indirect conductivity measurement of liquids in flexible containers

机译:间接测量柔性容器中液体的电导率

获取原文

摘要

This paper presents an indirect method for measuring the conductivity of liquid foods, packed in flexible TEA (Tetra Brik Aseptic) food-containers. The method is intended for intensive (100%) non-invasive sterility-testing of aseptically packed liquid food-products. It can also be applied for other containers, which have similar construction. An electric model is developed for the measured impedance, which consists of a few components. Some of them are dependent on the conductivity /spl sigma/ of the liquid. Relation is derived between the active component R of the measured impedance and the conductivity of the food. The sensitivity and the robustness of the method is investigated with respect to its application under industrial conditions and experimental results are presented.
机译:本文介绍了一种间接测量液态食品电导率的方法,该方法包装在柔性TEA(Tetra Brik无菌)食品容器中。该方法旨在对无菌包装的液态食品进行严格的(100%)无创无菌测试。它也可以应用于其他具有类似结构的容器。为测得的阻抗开发了一个电气模型,该模型包含一些组件。其中一些取决于液体的电导率/ spl sigma /。在测量的阻抗的活性成分R和食物的电导率之间得出关系。研究了该方法在工业条件下的应用的敏感性和鲁棒性,并给出了实验结果。